PREPARATIONS c3_sf11.html 3 pages/c3_sf11_ss2.html pages/c3_sf11_ss4.html RcButton-ENTER RcGroup-Cursor_keys RcGroup-Cursor_x5F_keys RcButton-ENTER RcButton-RETURN RcButton-ENTER RcButton-ENTER RcGroup-Cursor_keys RcGroup-Cursor_x5F_keys RcButton-ENTER RcGroup-Cursor_keys RcGroup-Cursor_x5F_keys PREPARATIONS Optimizing the speaker settings automatically (YPAO) Measuring at one listening position (single measure) 3 Error messages Warning messages Checking the measurement results

10Optimizing the speaker settings automatically (YPAO)

Measuring at one listening position (single measure)

Follow the procedure below to take a measurement when the “Multi Measure” box is unchecked. It takes about 5 minutes to perform the measurement.
  1. To start the measurement, use the cursor keys to select “Start” and press ENTER.
    The measurement will start in 10 seconds. Press ENTER again to start the measurement immediately.
    To cancel the measurement temporarily, press RETURN or VOLUME keys.
    The following screen appears on the TV when the measurement finishes.
    (when angle/height measurement is disabled)
    Proceed to Step 3.
    (when angle/height measurement is enabled)
    Proceed to Step 2.
  2. Perform the angle/height measurement.
    1. Attach the supplied pole to the center of the microphone base.
    2. Place the microphone base at the listening position and set the YPAO microphone to the position “1”.
      • We recommend using a tripod to place the microphone base at ear height. Use the tripod screws to fix the microphone base in place.
      • Do not move the microphone base until the fourth angle measurement finishes.
    3. Press ENTER to start the first angle measurement.
    4. In the same way, perform the angle measurement for the positions “2” and “3”.
    5. Set the YPAO microphone at the top of the pole and perform the fourth angle measurement.
      The following screen appears on the TV when the fourth angle measurement finishes.
  3. To check the measurement results, use the cursor keys to select “Measurement result” and press ENTER.
    After confirming the result, press RETURN to return to the “Measurement Finished” screen.
  4. To save the measurement results, use the cursor keys to select “Save” and press ENTER.
    The adjusted speaker settings are applied.
    To finish the measurement without saving the result, select “Cancel”.
  5. Disconnect the YPAO microphone from the unit.
This completes optimization of the speaker settings.
Caution
The YPAO microphone is sensitive to heat, so should not be placed anywhere where it could be exposed to direct sunlight or high temperatures (such as on top of AV equipment).