If a fader must be calibrated again

If a fader must be calibrated again, the [ON] or [CUE] key of the corresponding fader will flash.

Follow the steps below to do so.

  1. Use the Close button to close the popup screen “Found faders requiring adjustment. Please calibrate the faders again.” that opens on the screen.
  1. Press the Apply button on the screen.
  • The [SEL] keys of faders requiring recalibration light.
  1. Slide the corresponding fader to the highest and lowest positions several times.
  • Make sure the fader's slide action is smooth and not getting stuck.
  1. Perform the procedure described in “Calibrating faders” beginning at step 2.
  • If you perform this procedure multiple times and the popup message is still displayed, contact your Yamaha dealer listed at the end of the instruction manual.