Editing the internal parameters for OMNI IN of the control surface

This screen contains the following items.

a

Patch indication

Indicates the channel that is patched.

b

+48V button

Switches phantom power (+48V) on or off.

c

A.GAIN knob

Indicates the HA analog gain setting. Use the screen encoder to adjust the value.

d

Meters

This meter indicates the level of signals after passing through analog gain.

e

SILK ON button

Switches Silk on or off.

f

RED/BLUE selection button

Toggles between BLUE and RED: “BLUE” for solidity and power, and “RED” for sparkling energy.

g

SILK [TEXTURE] knob

Adjusts the TEXTURE parameter of Silk.

h

HPF button

Toggles the high pass filter on or off for each port.

NOTE

  • This is a parameter within the I/O rack. It is different than the HPF within the channel module of the control surface.

i

FREQUENCY knob

Sets the HPF cutoff frequency.

j

M/S button

Switches the M/S decoder on or off for each pair of channels.

k

S-GAIN knob

Adjusts the side gain of M/S.

NOTE
  • The OMNI IN of the CS-R5 or CS-R3 does not support the SILK function.(efg