SCENE Window

Use the SCENE window to manage the scenes in a project.

scene list

List Window

Use the List window to edit scenes. Scenes are saved in a project.

scene list2
Scene No.

Shows the number of the scene.

Title

Shows the title of the scene. Double-click to display a dialog window. Enter a title and a comment in the dialog window. Once the scene has been stored, it can be edited.

[Focus] button

Enables the Focus function. Click the button to select on/off.

The Focus function allows you to select which plug-ins to recall when recalling scene data.
[Focus Edit] button

Configures the Focus settings. Click to open the Recall Safe/Focus window.

Protect (Read Only) button

Prevents operations other than recalling and copying scenes (such as saving and deleting). Click the button to select on/off.

scene list3
Comment

Shows the comment. Double-click to display a dialog window. Once the scene has been stored, it can be edited.

You can enter only half-width alphanumeric characters in the comment.
Time Stamp

Shows the date and time.

scene list4
[Store] button

Stores settings with the current plug-in parameters as a scene. Click to open a dialog window. Enter a title and a comment in the dialog window. The Store operation is not possible if no plug-ins have been assigned to the rack. The Store operation is also not possible if Protect is on for the scene.

[Recall] button

Recalls a scene. Click to open a dialog window. Click [OK] in the dialog window to perform the Recall operation.

Context Menu

Right-click on the list to display the context menu. Click the desired operation in the menu.

Setting Description

Copy

Copies the selected scene.

Delete

Deletes the selected scene. This operation is not possible if Protect is on for the scene.

Edit

Edits the title and comment for the selected scene. This operation is not possible if Protect is on for the scene.

Recall Safe/Focus window

Use the Recall Safe/Focus window to configure the settings for Recall Safe and Focus. These settings can be configured by rack or by plug-in. The settings are saved in a project.

recall safe

Recall Safe

Configure the Recall Safe settings.

The Recall Safe function protects scene memory so that it is not recalled by a plug-in. Recall Safe setting information is saved independently of the scene data.
If you add a plug-in after creating a scene, it will not be recalled because the scene does not include that plug-in’s settings.
recall safe button
Rack name

Shows the name of the rack. Rack names cannot be edited in the Recall Safe/Focus window.

Rack color

Shows the rack color that was selected in the MAIN window. Rack color cannot be selected in the Recall Safe/Focus window.

Rack [Recall Safe] button

Turns Recall Safe on/off for the entire rack. Click the button to select on/off.

Plug-in [Recall Safe] buttons

Turns Recall Safe on/off for each Plug-in. Click the button to select on/off.

Focus

Configure the Focus settings.

Focus is a function that lets you set, which plug-in data will be recalled for each scene.
It is saved as part of the scene data. If it is set in duplicate with Recall Safe, Recall Safe takes precedence.
focus recall
No.

Shows the number of the scene.

[−] button

Switches the display to the scene information for the previous scene number. Click the button to switch the display.

[+] button

Switches the display to the scene information for the next scene number. Click the button to switch the display.

Title

Shows the title of the scene. Titles cannot be edited in the Recall Safe/Focus window.

Comment

Shows the comment for the scene. Comments cannot be edited in the Recall Safe/Focus window.

focus recall button
Rack name

Shows the name of the rack. Rack names cannot be edited in the Recall Safe/Focus window.

Rack color

Shows the rack color that was selected in the MAIN window. Rack color cannot be selected in the Recall Safe/Focus window.

Rack [Focus Recall]

Turns Focus Recall on/off for the entire rack. Click the button to select on/off.

Plug-in [Focus Safe] buttons

Turns Focus Recall on/off for each Plug-in. Click the button to select on/off.

A, B, C, D, Overview

In the Recall Safe/Focus window, you can switch the display between banks of 16 racks, or switch to the display specialized for Recall Safe state.

recall safe overview
[A], [B], [C], [D] bank buttons

Switches the display every 16 racks. You can switch between four banks: A, B, C, and D.

[Overview] button

Switches to a display of the Recall Safe state only. The items that are displayed are rack name, the Recall Safe state for the entire rack, and the Recall Safe state for each plug-in.