Link status |
informational |
port N link up(10-hdx) |
Agent port N linked up at 10 Mbps half-duplex. |
port N link up(10-fdx) |
Agent port N linked up at 10 Mbps full-duplex. |
port N link up(100-hdx) |
Agent port N linked up at 100 Mbps full-duplex. |
port N link up(100-fdx) |
Agent port N linked up at 100 Mbps full-duplex. |
port N link up(1000-fdx) |
Agent port N linked up at 1 Gbps full-duplex. |
port N link up(2500-fdx) |
Agent port N linked up at 2.5 Gbps full-duplex. |
port N link up(5000-fdx) |
Agent port N linked up at 5 Gbps full-duplex. |
port N link up(10000-fdx) |
Agent port N linked up at 10 Gbps full-duplex. |
port N link down |
Agent port N linked down. |
stack port(port *N_) link up |
The agent stack port (port *N_) linked up. |
stack port(port *N_) link down |
The agent stack port (port *N_) linked down. |
Loop detection |
informational |
port N loop detect |
A loop has occurred at agent port N. |
sa N loop detect |
A loop has occurred at agent static logical interface # N. |
po N loop detect |
A loop has occurred at agent LACP logical interface # N. |
Wireless Functions |
informational |
Airlink setting changed |
An agent wireless functionality setting was changed. |
PoE |
informational |
port N PoE state(supply-class0) |
Power supply was started to a class0 device at agent port N. |
port N PoE state(supply-class1) |
Power supply was started to a class1 device at agent port N. |
port N PoE state(supply-class2) |
Power supply was started to a class2 device at agent port N. |
port N PoE state(supply-class3) |
Power supply was started to a class3 device at agent port N. |
port N PoE state(supply-class4) |
Power supply was started to a class4 device at agent port N. |
port N PoE state(supply-class5) |
Power supply was started to a class5 device at agent port N. |
port N PoE state(supply-class6) |
Power supply was started to a class6 device at agent port N. |
port N PoE state(supply-class7) |
Power supply was started to a class7 device at agent port N. |
port N PoE state(supply-class8) |
Power supply was started to a class8 device at agent port N. |
port N PoE state(terminate) |
Power supply was stopped at agent port N. |
port N PoE state(overcurrent) |
Power supply was stopped at agent port N because an overcurrent occurred. |
port N PoE state(forced-terminate) |
Power supply was stopped at ports where class 3 (15.4 W) power was supplied by supplying class 4 (30 W) power at agent port N. |
port N PoE state(over-supply) |
Power supply was stopped because the peak power supply rate exceeded the maximum supply capacity at agent port N. |
port N PoE state(over-temperature) |
Power supply was stopped because a temperature error occurred at agent port N. |
port N PoE state(fanlock) |
Power supply was stopped because the fan stopped at agent port N. |
port N PoE state(power-failure) |
Power supply was stopped because the power supply failure occurred at agent port N. |
port N PoE state(class-failure) |
Power supply was stopped because a higher than specified power supply class was detected at agent port N. |
PoE state(over-guardband) |
The agent power supply level entered the guardband range. |
port N PoE state(pd-failure) |
Power supply was stopped because a power input error was detected at agent port N. |
port N PoE state(guardband-restrict) |
Power supply was stopped because a power supply that exceeded the guardband was detected at agent port N. |
PoE state error(over-supply) |
The agent power supply exceeded the maximum power supply capacity. |
PoE state error(stop-supply) |
The agent power supply stopped. |
PoE state error(power-failure) |
An agent power supply error occurred. |
PoE state error(over-temperature, stop)
Stack N PoE state error(over-temperature, stop) |
Power supply was stopped due to an agent temperature error.
Power supply was stopped due to an agent (stack ID: *N_) temperature error. |
PoE state error(over-temperature, normal)
Stack N PoE state error(over-temperature, normal) |
Power supply that stopped due to an agent temperature error was restored.
Power supply stopped due to an agent (stack ID: *N_) temperature error was restored. |
PoE state error(fanlock, stop)
Stack N PoE state error(fanlock, stop) |
Power supply was stopped because the agent fan stopped.
Power supply was stopped because the agent (stack ID: *N_) fan stopped. |
PoE state error(fanlock, normal)
Stack N PoE state error(fanlock, normal) |
Power supply stopped because an agent fan stopped was restored.
Power supply stopped because an agent (stack ID: *N_) fan stopped was restored. |
PoE state error(power-failure, stop)
Stack N PoE state error(power-failure, stop) |
Power supply was stopped due to an agent power supply abnormality.
Power supply was stopped due to an agent (stack ID: *N_) power supply abnormality. |
SFP Optical RX Level |
informational |
port N SFP RX power(low) |
The SFP optical RX level decreased below the lower limit threshold value at agent port N. |
port N SFP RX power(high) |
The SFP optical RX level exceeded the upper limit threshold value at agent port N. |
port N SFP RX power(normal) |
The SFP optical RX level at agent port N returned to normal. |
Send Queue Usage |
informational |
port N queue Q usage rate(busy) |
The sending load at agent port N is high (QoS transmission queue: *Q_) |
port N queue Q usage rate(full) |
The sending load at agent port N reached the upper limit (QoS transmission queue: *Q_) |
port N queue Q usage rate(recovered) |
The sending load at Agent port N returned to normal (QoS transmission queue: *Q_) |
Terminal Monitoring |
informational |
ping: *ip-address_(description) state(DOWN) |
Ping monitoring indicated *ip-address_(description) has gone down. |
ping: *ip-address_(description) state(UP) |
ping monitoring indicated *ip-address_(description) is now operating. |
ping: *ip-address_(description) state(IDLE) |
ip-address(description) is not being monitored by ping monitoring. |
Frame Counter: *port_(description) state(DOWN) |
Monitoring according to frame reception volume indicates *port_(description) has gone down. |
Frame Counter: *port_(description) state(UP) |
Monitoring according to frame reception volume indicates *port_(description) is now operating. |
Frame Counter: *port_(description) state(IDLE) |
port(description) is not being monitored according to frame reception volume. |
LLDP: *port_(description) state(DOWN) |
LLDP frame monitoring indicates *port_(description) has gone down. |
LLDP: *port_(description) state(UP) |
LLDP frame monitoring indicates *port_(description) is now operating. |
LLDP: *port_(description) state(IDLE) |
port(description) is not being monitored by LLDP frame monitoring. |
Power supply |
informational |
Power voltage(high)
Stack N Power voltage(high) |
The agent power supply voltage exceeded the upper threshold value.
The agent (stack ID: *N_) power supply voltage exceeded the upper threshold value. |
Power current(high)
Stack N Power current(high) |
An overcurrent occurred in the agent power supply.
An overcurrent occurred in the agent (stack ID: *N_) power supply. |
Fan |
informational |
Fan lock |
The agent fan stopped. |
FAN control(high)
Stack N FAN control(high) |
The agent fan rpm increased.
The agent (stack ID: *N_) fan rpm increased. |
FAN control(low)
Stack N FAN control(low) |
The agent fan rpm decreased.
The agent (stack ID: *N_) fan rpm decreased. |
FAN X (stop)
Stack N FAN X (stop) |
The agent fan (FAN *X_) stopped.
The agent (stack ID: *N_) fan (FAN *X_) stopped. |
FAN X (normal)
Stack N FAN X (normal) |
The agent fan (FAN *X_) was restored.
The agent (stack ID: *N_) fan (FAN *X_) was restored. |
Temperature |
informational |
CPU temperature(high)
Stack N CPU temperature(high) |
The agent CPU temperature exceeded the threshold value.
The agent (stack ID: *N_) CPU temperature exceeded the threshold value. |
CPU temperature(normal)
Stack N CPU temperature(normal) |
The agent CPU temperature returned to normal.
The agent (stack ID: *N_) CPU temperature returned to normal. |
CPU temperature error(alarm)
Stack N CPU temperature error(alarm) |
An agent CPU temperature error occurred.
The agent (stack ID: *N_) CPU temperature error occurred. |
CPU temperature error(normal)
Stack N CPU temperature error(normal) |
The agent CPU temperature error was resolved.
The agent (stack ID: *N_) CPU temperature error was resolved. |
PHY temperature(high)
Stack N PHY temperature(high) |
The agent PHY temperature exceeded the threshold value.
The agent (stack ID: *N_) PHY temperature exceeded the threshold value. |
PHY temperature(normal)
Stack N PHY temperature(normal) |
The agent PHY temperature returned to normal.
The agent (stack ID: *N_) PHY temperature returned to normal. |
PHY temperature error(alarm)
Stack N PHY temperature error(alarm) |
An agent PHY temperature error occurred.
The agent (stack ID: *N_) PHY temperature error occurred. |
PHY temperature error(normal)
Stack N PHY temperature error(normal) |
The agent PHY temperature error was resolved.
The agent (stack ID: *N_) PHY temperature error was resolved. |
SFP temperature(high)
Stack N SFP temperature(high) |
The agent SFP module temperature exceeded the threshold value.
The agent (stack ID: *N_) SFP module temperature exceeded the threshold value. |
SFP temperature(normal)
Stack N SFP temperature(normal) |
The agent SFP module temperature returned to normal.
The agent (stack ID: *N_) SFP module temperature returned to normal. |
SFP temperature error(alarm)
Stack N SFP temperature error(alarm) |
An agent SFP module temperature error occurred.
The agent (stack ID: *N_) SFP module temperature error occurred. |
SFP temperature error(normal)
Stack N SFP temperature error(normal) |
The agent SFP module temperature error was resolved.
The agent (stack ID: *N_) SFP module temperature error was resolved. |
Unit temperature(high)
Stack N Unit temperature(high) |
The agent unit temperature exceeded the threshold value.
The agent (stack ID: *N_) unit temperature exceeded the threshold value. |
Unit temperature(normal)
Stack N Unit temperature(normal) |
The agent unit temperature returned to normal.
The agent (stack ID: *N_) unit temperature returned to normal. |
Unit temperature error(alarm)
Stack N Unit temperature error(alarm) |
A temperature error occurred in an agent unit.
The agent (stack ID: *N_) unit temperature error occurred. |
Unit temperature error(normal)
Stack N Unit temperature error(normal) |
The temperature error in the agent unit was resolved.
The agent (stack ID: *N_) unit temperature error was resolved. |
PSE temperature(high)
Stack N PSE temperature(high) |
The agent PSE temperature exceeded the threshold value.
The agent (stack ID: *N_) PSE temperature exceeded the threshold value. |
PSE temperature(normal)
Stack N PSE temperature(normal) |
The agent PSE temperature returned to normal.
The agent (stack ID: *N_) PSE temperature returned to normal. |
PSE temperature error(alarm)
Stack N PSE temperature error(alarm) |
An agent PSE temperature error occurred.
The agent (stack ID: *N_) PSE temperature error occurred. |
PSE temperature error(normal)
Stack N PSE temperature error(normal) |
The agent PSE temperature error was resolved.
The agent (stack ID: *N_) PSE temperature error was resolved. |
MAC temperature(high)
Stack N MAC temperature(high) |
The agent MAC temperature exceeded the threshold value.
The agent (stack ID: *N_) MAC temperature exceeded the threshold value. |
MAC temperature(normal)
Stack N MAC temperature(normal) |
The agent MAC temperature returned to normal.
The agent (stack ID: *N_) MAC temperature returned to normal. |
MAC temperature error(alarm)
Stack N MAC temperature error(alarm) |
An agent MAC temperature error occurred.
The agent (stack ID: *N_) MAC temperature error occurred. |
MAC temperature error(normal)
Stack N MAC temperature error(normal) |
The agent MAC temperature error was resolved.
The agent (stack ID: *N_) MAC temperature error was resolved. |
Thermal sensor(alarm)
Stack N Thermal sensor(alarm) |
An agent temperature sensor error occurred.
The agent (stack ID: *N_) temperature sensor error occurred. |
Config Management |
informational |
Executing a config … progress % (file) |
Agent config file (file) settings are being restored. (progress%). |
Finished executing a config (file) |
Finished restoring the agent config file (file). |
line: errmsg (file) |
An errmsg error occurred on line line while restoring the agent config file (file). |
Manager Duplication |
informational |
l2ms-manager-duplication(occur). (addr, port *X_) |
A duplicate L2MS manager was detected at an agent. (MAC address, port number where duplication was detected) |
l2ms-manager-duplication(stop). (addr, port *X_) |
The L2MS manager duplication at the agent was resolved. (MAC address, port number where duplication was detected) |
Function |
informational |
unsupported function(function) |
The agent firmware does not support the corresponding protocol.
The _function* part shows one of the following:
Setting info
Status l2ms info
SFP RX power
Qos queue rate
Qos queue rate2
Terminal monitoring
System monitoring
Note: Only output the first time after the “Find agent” message. The log output is suppressed after the first time.
These are reset once link down is detected. |