Performing Initialization
10. Performing Initialization
10.1. Initializing the Unit (Restoring the Factory Settings)
There are two methods by which to restore the factory settings.
■ Performing a forced initialization
If an error occurs in the unit’s internal memory and you become unable to operate the unit, follow the steps below.
1. Turn off the power to the unit.
2. Turn on the power while pressing and holding the [MENU/HOME] and [
] (Back) / [PEAK] keys simultaneously, and then wait until the home screen is displayed (in about 20 seconds) while you continue to hold down the two keys.
The message “FACTORY INITIALIZE ACCEPTED!” appears, and the initialization process of this unit begins.
NOTE
If you perform a forced initialization while the panel is locked, the panel will be unlocked.
3. When the message “INITIALIZE DONE. REBOOT?” appears, turn the encoder with switch to select OK, and then press it to confirm. The unit reboots.
NOTE
After the initialization is complete, be sure to select OK to reboot the unit before starting to use it.
■ Selecting FACTORY PRESET on screen
1. While the MENU TOP screen is displayed, turn the encoder with switch to select SETUP, and then press it to confirm.
2. In the SETUP menu, turn the encoder with switch to select INITIALIZE, and then press it to confirm.
3. Turn the encoder with switch to select FACTORY PRESET.
4. When the message “FACTORY PRESET INITIALIZE?” appears, turn the encoder with switch to select OK, and then press it to confirm.
The initialization process begins.
NOTE
If you turn the encoder with switch to select CANCEL, and then press it to confirm, the initialization process will not begin, and the previous screen will be displayed.
5. When the message “INITIALIZE DONE. REBOOT?” appears, turn the encoder with switch to select OK, and then press it to confirm. The unit reboots.
NOTE
After the initialization is complete, be sure to select OK to reboot the unit before starting to use it.
Related link(s)
“
SETUP menu
”
10.2. Initializing the Current Parameters
Follow the steps below to reset the HA parameter values to the factory settings.
1. While the MENU TOP screen is displayed, turn the encoder with switch to select SETUP, and then press it to confirm.
2. In the SETUP menu, turn the encoder with switch to select INITIALIZE, and then press it to confirm.
3. Turn the encoder with switch to select CURRENT PARAMETERS.
4. When the message “CURRENT PARAMETERS INITIALIZE?” appears, turn the encoder with switch to select OK, and then press it to confirm.
Initialization of the HA parameter values begins.
NOTE
If you turn the encoder with switch to select CANCEL, and then press it to confirm, the initialization process will not begin, and the previous screen will be displayed.
Related link(s)
“
SETUP menu
”
10.3. Initializing the Dante Settings
Follow the steps below to reset the Dante parameter values to the factory settings.
1. While the MENU TOP screen is displayed, turn the encoder with switch to select SETUP, and then press it to confirm.
2. In the SETUP menu, turn the encoder with switch to select INITIALIZE, and then press it to confirm.
3. Turn the encoder with switch to select DANTE SETTINGS.
4. When the message “DANTE SETTINGS INITIALIZE?” appears, turn the encoder with switch to select OK, and then press it to confirm.
Initialization of the Dante settings begins.
NOTE
If you turn the encoder with switch to select CANCEL, and then press it to confirm, the initialization process will not begin, and the previous screen will be displayed.
Related link(s)
“
SETUP menu
”
10.4. Factory-set Initial Values
The following table provides the factory-set initial values.
| Parameter | Initial value | ||
|---|---|---|---|
|
SETUP |
UNIT ID |
Y001 |
|
|
START UP (START UP Mode) |
REFRESH with MUTE |
||
|
SEC.PORT (SECONDARY PORT) |
DAISY CHAIN |
||
|
FAN SPEED |
LOW |
||
|
BRIGHTNESS |
20 |
||
|
CONTRAST |
10 |
||
|
LED COLOR |
GREEN |
||
|
LED ACTION |
ON |
||
|
DIMMER |
30 sec |
||
|
F16 CONFIG (RUio16FLX-D only) |
IN: 16, OUT: 0, AES: 0 |
||
|
CONTROL |
NW PORT |
NETWORK MODE |
STATIC IP |
|
IP ADDRESS |
192.168.0.2 |
||
|
SUBNET MASK |
255.255.255.0 |
||
|
DEFAULT GW |
192.168.0.1 |
||
|
CONTROL |
DANTE PORT |
NETWORK MODE |
DHCP |
|
IP ADDRESS |
(determined by DHCP or Link Local) |
||
|
SUBNET MASK |
(determined by DHCP or Link Local) |
||
|
DEFAULT GW |
(determined by DHCP or Link Local) |
||
|
HA parameter |
HA Gain |
0 dB |
|
|
+48V |
OFF |
||
|
HPF |
OFF, 80 Hz |
||
|
GC (GAIN COMPENSATION) |
OFF, 0 dB |
||
|
Dante settings |
Sample Rate |
96 kHz (follower), Pull-up/down = None^*1^ |
|
|
Latency |
1.0 msec |
||
|
Encoding |
PCM 24-bit |
||
|
Dante Redundancy |
Switched |
||
|
IP Address |
Auto |
||
|
Device Label |
Y001-Yamaha-RUio1608SB-D-nnnnnn
*2
|
||
|
Channel Label |
<Channel number> |
||
|
AES67 Mode |
Disabled |
||
|
Device Lock |
Unlock |
||
*1 The default setting of the Sample Rate is 96 kHz. Please be careful when using this product in combination with devices that do not support 96 kHz (such as CL or QL series).
*2 "nnnnnn" represents the lowest six digits of the Dante Primary MAC Address.